6.2.5 Setting the BIM Rack/Shelf ID
The location information (rack/shelf) of the BIM module belonging to this tenant must be
configured. The valid values for these MIB fields are strings of 1-16 characters (see Hub
Equipment Identification section above for more information about the values that should be
used). The Hub Config Process will push these ID strings down to the Network Node MIB of
the CPU that controls this BIM. This will allow the NMS to identify the location of the BIM
when it is reporting a fault condition. The MIB fields are:
transceptBtsConnectionTable.transceptBtsConnectionBimRackID
and
transceptBtsConnectionTable.transceptBtsConnectionBimShelfID
6.2.6 Designating the Tenant Hardware
The BTS Connection MIB contains several fields pertaining to the location of the tenant-
specific hardware. Though every effort was made to minimize the configuration necessary,
some of the connections made between hardware are not automatically detectable, and
therefore require some manual intervention.
Using the information in the Hub Cabling section above, the I2C addresses of the RF modules
belonging to the tenant being configured must be set as follows:
The BIM I2C Address (bus/slot) will automatically be filled in by the Hub Config
Process. The MIB fields are:
transceptBtsConnectionTable.transceptBtsConnectionBimI2cBus
and
transceptBtsConnectionTable.transceptBtsConnectionBimI2cSlot
The BIM module belonging to this tenant must have RF connections to either one or two
HDC modules. Based on the table in the Hub Cabling section above, select the I2C Bus
and Slot of the HDC module(s) based on the position of the module(s) in the RF chassis.
As indicated in the Hub Cabling section above, the two HDC’s belonging to a single
tenant (i.e. having RF connections to the same BIM module) should be co-located in the
RF chassis, with only an FSC module separating them. The MIB fields are: