ADCP-75-192 • Issue D • October 2005 • Section 2: Description
Page 2-26
2005, ADC Telecommunications, Inc.
SMR/CELL/PCS LED – Yellow LED lighted indicating BIM band configuration
I2C Address display – Displays I2C address, 0-5
SMR/CELL/PCS – Indicates Protocol
PWR - Indicates Power is applied
FAULT – Indicates BIM Fault
(1) BAS E S TATION DUP LEXED
RF CONNECTORS
(6) RECEIVE P RIMARY AND
DIVERSITY RF CONNECTORS
(2) TRANSMIT SIMP LEXED
RF CONNECTORS
(5) LED BAND
INTERFACE INDICATORS
(3) FAULT
(4) P OWER
Figure 2-19. BTS Interface Module Front Panel
Table 2-18. BIM Front Panel User Interface
REFN
o.
USER INTERFACE
DESIGNATION
DEVICE
FUNCTIONAL DESCRIPTION
1 Base Station
Duplexed RF
Connectors
SMA RF forward and reverse path inputs
2 Transmit Simplexed
RF Connectors
SMA RF forward path outputs to Hub
3 Fault LED Single-colored LED
(Red)
Status indicator turns red when module has
failed.
4 Power LED Single-colored LED
(Green)
Status indicator turns green when module
has power.
5 LED Band Indicators Single-colored LED
(Yellow)
Status indicator turns yellow showing
which band is active with unit
6 Receive Simplexed
RF Connectors
SMA RF reverse path inputs from Hub
4.8 Attenuator Shelf
The original BIM had the attenuators mounted internally to the BIM. The later version of the
BIM moved the attenuators outside the BIM and mounted to an attenuator shelf. The attenuator
shelf is mounted at the top of the Hub rack. It can hold up to twelve (12) 50 watt attenuators.