User Manual
ADCP-75-192 • Issue D • October 2005 • Section 3: Network and System Installation and Setup
Page 3-6
2005, ADC Telecommunications, Inc.
6.2 BTS Connection MIB
Within the Hub Master node, the BTS Connection MIB is used to create new tenant base
station sector instances (simply called "tenants" from here on) to be configured, monitored, and
controlled in the Digivance CXD system. In order to create a new tenant in the Digivance
CXD system, the Hub Config Process in the Hub Master must first locate a unique BIM
instance controlled by one of the Hub CPUs. This requires that the Hub Node first be
configured such that the CPU Rack ID and Chassis ID are known (described in Section 11.1 of
this document). The software in the Hub Master continues to send requests to all configured
Hub Nodes to determine if there are any BIM modules that have come online.
When a never-been-seen-before BIM module is located, the Hub Config Process creates an
"Unconfigured" tenant in the BTS Connection MIB. This can be seen by noticing that the
Tenant ID in the BTS Connection MIB is "UnconfiguredX", where X is 1-96. Also, it can be
seen that the CPU Rack and Chassis IDs are filled in and the BIM I2C Bus/Slot information is
filled in. At this point, the rest of this tenant must be configured manually.
6.2.1 Setting the Tenant Name
Tenant Name is the name of the Wireless Service Provider (WSP). The allowable value is a
string length of 1-17 characters. The MIB field is:
transceptBtsConnectionTable.transceptBtsConnectionTenantName.
6.2.2 Setting the BTS ID
Since WSP’s may have more than one base station (BTS) in the system, it is important to
uniquely identify them - the allowable value is a string of 1-8 characters. The MIB field is:
transceptBtsConnectionTable.transceptBtsConnectionBTSID.
6.2.3 Setting the BTS Sector
The BTS Sector field of the BTS Connection MIB is an enumerated value, where the allowable
selections are ALPHA (0), BETA (1), or GAMMA (2). The MIB field is:
transceptBtsConnectionTable.transceptBtsConnectionBTSSector.
6.2.4 Setting the Tenant Band
The Tenant Band field of the BTS Connection MIB is an enumerated value, where the
allowable selections are the bands supported by the Digivance CXD system, currently:
No Band (0) - no band selected, will not result in a configured tenant
US1900A (1) - PCS band A
US1900B (2) - PCS band B
US1900C (3) - PCS band C
US1900D (4) - PCS band D