7.2 Ran Up Converter (RUC2.X or RUC3)
The RAN Up Converter (RUC), shown in Figure 2-29, takes IF signals from a DIF signal
generated by a SIF and up converts the signals to RF. The RF outputs of the RUC are
connected to the RFA’s using coax cable jumpers. The RUC is used to monitor and control the
RFA and communicates over the provided cable using I2C. The references for the RUC user
interface are shown in Table 2-20. Two versions of the RUC, the RUC2.X and RUC3, are
available.
(4) FAULT LED
(5) CHANNEL 2/4 OUT
(6) P OWER LED
(8) P A CNTL 1/3
(2) COM 1/3
(3) COM 2/4
(7) P A CNTL 2/4
(1) CHANNEL 1/3 OUT
Figure 2-29. RUC Front Panel
Table 2-20. RUC User Interface
REF
No.
USER INTERFACE
DESIGNATION
DEVICE FUNCTIONAL DESCRIPTION
1 Channel 1/3 Out
Connector
SMA connector RF output for signal coming from RAN
SIF OUT channel 1 or 3
2 COM 1/3 LED Single-colored LED
(Yellow)
Status indicator turns yellow when DIF lock
to SIF Channel 1 or 3
3 COM 2/4 LED Single-colored LED
(Yellow)
Status indicator turns yellow when DIF lock
to SIF Channel 2 or 4
4 Fault LED Single-colored LED
(Red)
Status indicator turns red when module has
failed. Indicator is lit during start-up until
the module has initialized. Indicator will
blink after module receives a system clock
and is awaiting initialization
5 Channel 2/4 Out
Connector
SMA connector RF output for signal coming from RAN
SIF OUT channel 2 or 4
6 Power LED Single-colored LED
(Green)
Status indicator turns green when module
has power.
continued