User's Manual

Table Of Contents
PN 8700-10 Help Hot Line (U.S. only): 1-800-530-9960 6-33
620003-0
PRELIMINARY Connecting Multiple Main Hubs
Connecting Multiple Main Hubs to a Duplex Repeater
or Base Station
You will need the following:
2 hybrid power combiner/splitters; one for uplink and one for downlink (2x1 for
two Main Hubs, 3x1 for three, 4x1 for four, etc.)
2 N-male to N-male coaxial jumper cables to connect each Main Hub to the power
combiner/splitters
1 circulator
1 N-male to N-male coaxial jumper cable between each circulator and the repeater
or base station
1 N-male to N-male coaxial jumper cable1 between each circulator and power
combiner/splitter
Figure 6-5 on page 6-31 illustrates this procedure.
1. Connect the Circulator to the power combiner/splitters and to the repeater or base
station using one N-male to N-male coaxial jumper cable.
2. Connect each power combiner/splitter to the circulator using one N-male to
N-male coaxial jumper cable.
3. Connect the power combiner/splitter to the Main Hubs:
a. From the first Main Hub’s UPLINK port to the first power combiner/splitter
b. From the first Main Hub’s DOWNLINK port to the second power com-
biner/splitter
c. From the second Main Hub’s UPLINK port to the first power combiner/splitter
d. From the second Main Hub’s DOWNLINK port to the second power com-
biner/splitter
4. Check Main Hub LEDs.
After connecting and powering on the Main Hub, check all LEDs to ensure that
the system is operating properly.
NOTE: Use a 50 ohm terminator on any unused power combiner/splitter ports.