User's Manual
Table Of Contents
- SECTION 1 General Information
- SECTION 2 InterReach™ Unison System Description
- SECTION 3 Unison Main Hub
- SECTION 4 Unison Expansion Hub
- SECTION 5 Unison Remote Access Unit
- SECTION 6 Installing Unison Components
- 6.1 Installation Requirements
- 6.2 Safety Precautions
- 6.3 Preparing for System Installation
- 6.4 Unison Component Installation Procedures
- 6.5 Starting and Configuring the System
- 6.6 Interfacing a Main Hub to a Base Station or Roof-top Antenna
- 6.7 Connecting Contact Alarms to a Unison System
- SECTION 7 Installing and Using the AdminManager Software
- SECTION 8 Designing a Unison Solution
- 8.1 Maximum Output Power per Carrier at RAU
- 8.2 Estimating RF Coverage
- 8.3 System Gain
- 8.4 Link Budget Analysis
- 8.4.1 Elements of a Link Budget for Narrowband Standards
- 8.4.2 Narrowband Link Budget Analysis for a Microcell Application
- 8.4.3 Elements of a Link Budget for CDMA Standards
- 8.4.4 Spread Spectrum Link Budget Analysis for a Microcell Application
- 8.4.5 Considerations for Re-Radiation (over-the-air) Systems
- 8.5 Optical Power Budget
- 8.6 Connecting a Main Hub to a Base Station
- 8.7 Designing for a Neutral Host System
- SECTION 9 Replacing Unison Components in an Operating System
- SECTION 10 Maintenance, Troubleshooting, and Technical Assistance
- APPENDIX A Cables and Connectors
- APPENDIX B Compliance
- APPENDIX C Glossary
Designing a Unison Solution PRELIMINARY
8-46 InterReach Unison User Guide and Reference Manual
PN 8700-10
620003-0
The following table lists the typical losses from the configuration shown in Figure 1.
NOTE: Where known losses are less than 1.7 dB (1310 or 1550), the potential reach
will exceed 15 km. For CDMA, care must be taken to ensure that the fiber-induced
latencies do not conflict with the Operator’s PN offset plan.
Description
Downlink
(1310 nm)
Loss
Subtotal
Uplink
(1550 nm)
Loss
Subtotal Source
Optical Power Budget (dB) 7 5.5 LGC Wireless
Inside Plant Cable Loss (dB/km) 0.5 0.5 OCC/
CommScope
Cable Length (km)
a
a. This length will vary for each individual building.
1.2 0.6 1.2 0.6
SMF Jumper Loss (approx. dB/km)
b
b. It is assumed that the SMF jumpers are less than a meter and therefore their loss is negligible.
1.0 0.0 0.5 0.0
SC/APC Insertion Loss (dB): 4 used 0.25 1.0 0.25 1.0 Siecor
Fusion Splice Loss (dB): 6 used 0.05 0.3 0.05 0.3 Alcoa Fujikura
Losses (dB) 1.9 1.9
Available budget for OSP (dB)
(Optical Power Budget – Known Losses) 5.1 3.6
Outside Plant Cable Loss (dB/km) 0.35 0.25 CommScope
Optical Power Budget
– Known Losses
÷ Outside Plant Cable Loss
= Potential Fiber Length (km)
c
c. Actual fiber length may vary due to the quantity and quality of fiber splices in the OSP network.
7
– 5.1
÷ 0.35
14.57
5.5
– 3.6
÷ 0.25
14.40