PRELIMINARY Coverage Distance
For reference, Tables 8-19 through 8-25 show the distance covered by an antenna for
various in-building environments. The following assumptions were made:
Path loss Equation (3)
6 dBm output per carrier at the RAU output
3 dBi antenna gain
RSSI = –85 dBm (typical for narrowband protocols, but not for spread-spec-
trum protocols)
Table 8-19 Approximate Radiated Distance from Antenna
for 800 MHz Cellular Applications
Facility
Distance from Antenna
Meters Feet
Manufacturing 63 205
Hospital 39 129
Airport 63 205
Retail 55 181
Warehouse 63 205
Parking Garage 73 241
Office: 80% cubicle/20% hard wall 55 181
Office: 50% cubicle/50% hard wall 47 154
Office: 20% cubicle/80% hard wall 39 129
Table 8-20 Approximate Radiated Distance from Antenna
for 800 MHz iDEN Applications
Facility
Distance from Antenna
Meters Feet
Manufacturing 64 208
Hospital 40 131
Airport 64 208
Retail 56 184
Warehouse 64 208
Parking Garage 75 244
Office: 80% cubicle/20% hard wall 56 184
Office: 50% cubicle/50% hard wall 48 156
Office: 20% cubicle/80% hard wall 40 131