Connecting a Main Hub to an In-Building Base Station
Connecting a Simplex Base Station to a Main Hub:
1. Connect an N-male to N-male coaxial cable to the transmit simplex connector on
the base station.
2. Connect the other end of the N-male to N-male coaxial cable to the FORWARD
simplex connector on the Main Hub.
3. Connect an N-male to N-male coaxial cable to the receive simplex connector on
the base station.
4. Connect the other end of the N-male to N-male coaxial cable to the REVERSE sim-
plex connector on the Main Hub.
Figure 9-1 Simplex Base Station to LGCell Main Hub
REVERSE FORWARD DUPLEX
DIAGNOSTIC 2 DIAGNOSTIC 1
Microcellular
N-male to N-male
Coaxial Cable
Base Station
Simplex
T1/E1 to
Mobile
Switching
Center
Insert attenuator, if needed