User's Manual Part 2

Installing the LGCell
9-18 LGCell 4.0 Installation, Operation, and Reference Manual PN 8100-40
620004-0 Rev. E
To connect 5 LGCell systems to a base station’s alarms:
Connect the alarm cable’s J2 through J6 connectors to the
DIAGNOSTIC 1 port on
five Main Hubs.
The J7 connector is unused and is left unterminated.
To connect more than 5 LGCell systems to a base station’s alarms:
1. Connect the first alarm cable’s J2 through J5 connectors to the DIAGNOSTIC 1 port
on four Main Hubs.
2. Connect the J1 connector of the second daisy-chain cable to the J6 connector on
the first cable; J7 is unused.
You can add daisy-chain cables to accommodate up to 21 Main Hubs in a single
chain.
3. Connect the J7 connector to the lowest numbered unused male connector (J2
through J6), if there is one.