User's Manual Part 1
LGCell Remote Access Unit
5-6 LGCell 4.0 Installation, Operation, and Reference Manual PN 8100-40
620004-0 Rev. E
5.3 LGCell Remote Access Unit Specifications
Table 5-2 RAU Specifications (Single Band Unless Indicated Otherwise)
Specification Description
Dimensions (H
× W × D)
Single Band
Dual Band (vertical): 900/1800, 1800/1800
Dual Band (horizontal): 800/900, 800/1900
36 mm
× 110 mm × 140 mm (1.4 in. × 4.3 in. × 5.5 in.)
68 mm
× 157 mm × 203 mm (2.7 in. × 6.2 in. × 8 in.)
35 mm
× 261 mm × 200 mm (1.4 in. × 10.3 in. × 7.9 in)
Weight
Single Band
Dual Band: all
< 0.4 kg (< 0.9 lb)
< 0.8 kg (< 1.8 lb)
Operating Temperature 0° to 45°C (32° to 113°F)
Operating Humidity, non-condensing 5% to 95%
RF Connectors
Single Band
Dual Band: 900/1800, 800/900, 800/1900
Dual Band: 1800/1800
1 RJ-45; 1, SMA female
2 RJ-45; 1, SMA female
2 RJ-45; 2 SMA female
LED Alarm and Status Indicators Power, Sync
Power Consumption
Typical
Maximum
5.7 W
7.5 W
Frequencies • 800 MHz Cellular*
• 800 MHz iDEN
•900 MHz GSM*
• 900 MHz EGSM
• 1800 MHz DCS
• 1900 MHz PCS
MTBF (hours) 965,000
* The 800 MHz CDMA/900 MHz GSM RAU is designed for use in China. It comprises one 800 MHz Cellular and
one 900 MHz GSM single band RAU as well as a diplexer that filters and combines the bands.