116 Link CX User Manual, Version A
indicates the receive signal level is below the detection level."
::= }link_cx_status 2}
bitErrorRate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The estimated bit error rate (BER), in errors per 10^8 bits.
A returned value of 0 indicates zero bit errors in 10^8 bits.
A returned value of 1 indicates an estimated BER of 1x10^-8.
A returned value of 10 indicates an estimated BER of 1x10^-7,
and so on."
::= }link_cx_status 3}
losAlarmStatus OBJECT-TYPE -- DS3 interface alarm condition
SYNTAX INTEGER {
normal(1),
alarm(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A value of 1 indicates a DS3 connection is present.
A value of 2 indicates the DS3 connection has been lost.
If ds3LosAlarmControl = disabled, losAlarmStatus will
always be normal."
::= }link_cx_status 4}
txSynthLockAlarmStatus OBJECT-TYPE -- local alarm condition
SYNTAX INTEGER {
normal(1),
alarm(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Tx synthesizer lock status.
A value of 1 indicates the Tx synthesizer is locked.
A value of 2 indicates the Tx synthesizer is unlocked"
::= }link_cx_status 5}
rxSynthLockAlarmStatus OBJECT-TYPE -- local alarm condition
SYNTAX INTEGER {
normal(1),
alarm(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Rx synthesizer lock status.