User's Manual

Table Of Contents
72 Link CX User Manual, Version A
55 If the Link CX is equipped with an external antenna, follow the guidelines in Appendix 4 and
connect a customer-supplied solid wire or tape (not braided) grounding wire to the
grounding lug on the back of the antenna.
Connect the other end of this wire to a proper grounding point.
4-5.4 Sealing the Data and Power Cable Connectors
The cables that are terminated outdoors must be sealed at each exposed end to prevent moisture
incursion and damage. For all exposed connectors, including those between an external antenna and
the Link CX, perform the following:
56 Wrap each connector with vinyl or plastic electrical tape.
57 Wrap the vinyl or plastic electrical tape with butyl rubber amalgamating tape to prevent
moisture from permeating the connector.
58 Wrap the butyl rubber amalgamating tape with vinyl or plastic electrical tape.
Figure 4-32 Connecting an Earth Ground to the Link CX
IW094202
To Earth Ground
Grounding
Lug
Customer-Supplied
Grounding Wire or Tape