User's Manual
Table Of Contents
- interWave WaveNet Link CX User Manual
- One - System Description
- 1-1 General
- 1-2 System Overview
- 1-3 Features
- 1-4 LinkCX Basic Structure
- 1-4.1 Radio Links
- 1-4.2 Data Stream
- 1-4.3 LinkCX Models
- 1-4.4 Mounting and Antenna Alignment
- 1-4.5 Interface Connectors and Indicators
- 1-4.6 Cables
- 1-4.7 Integral Antenna
- 1-4.8 External Antenna
- 1-4.9 Configuration, Operation, and Monitoring
- 1-4.10 SNMP
- 1-4.11 LinkCX Network Management Architecture
- 1-4.12 NMS Connectivity
- 1-4.13 Web-Based GUI Access Security
- 1-4.14 GUI Functions
- 1-5 Typical Applications
- 1-5.1 Internet (ISP)
- 1-5.2 Private Network Wireless Bridged LANs and WANs
- 1-5.3 PCS/PCN and Cellular Networks
- 1-5.4 Wireless Local Loop Networks and Local Exchange Bypass
- 1-5.5 Business Bypass and Local Exchange Bypass
- 1-5.6 Backhaul for Wireless MTU and MTU Access
- 1-5.7 Wireless Mesh Backhaul Networks
- 1-5.8 Wireless ATM Mesh Distribution with StreamNet
- 1-6 Specifications
- Two - Installation Steering Guide
- Three - Installation Planning
- Four - Installing the Link CX
- Five - Final Link CX Setup
- Six - Monitoring and Trend Analysis
- Seven - Troubleshooting the Link CX
- Appendix 1 - Interface Cable Pinouts
- Appendix 2 - Technical Specifications
- Appendix 3 - Using the Web-Based GUI User Interface
- Appendix 4 - Grounding and Lightning Protection
- Appendix 4 - Enterprise MIBs and Traps
Installing the Link CX 49
Non-Adjustable Elevation Single Link CX Bracket
A See Figure 4-7. Assemble the two steel band clamps to the pole mount bracket.
B Wrap the clamps around the pole and finger tighten their clamp screws. The bracket
should be able to pivot around the pole, allowing horizontal alignment.
C Install the pole-mount bracket.
• When you are installing a Link CX with an integral antenna, use a compass or
optical aid to coarsely align the pole mount bracket with the far-end antenna
location. Continue with Section 4-3.2.
• When you are installing a Link CX with an external antenna, position the bracket
near enough to the planned antenna location so that the Link CX does not inter-
fere with antenna alignment and so the factory-supplied 2 m (6.5 ft.) antenna
cable can be connected to both units. Continue with Section 4-3.2.
Adjustable Elevation Single Link CX Bracket
A See Figure 4-8. Assemble the two steel band clamps to the pole mount bracket.
B Wrap the clamps around the pole and finger tighten their clamp screws. The bracket
should be able to pivot around the pole, allowing horizontal alignment.
C Install the pole-mount bracket. Use a compass or optical aid to coarsely align the pole
mount bracket with the far-end antenna location.
D Assemble the rest of the bracket parts as shown in Figure 4-8. Use a level to ensure
that the coarse elevation is 0°. Continue with Section 4-3.2.
Figure 4-7 Non-Adjustable Elevation Single Link CX Bracket
IW099201
Pole Mount
Bracket
Steel Band
Clamps