User's Manual

Table Of Contents
42 Link CX User Manual, Version A
4-2.2 Logging In to the Link CX Built-In Web Server
After you have connected and powered up the Link CX and the Craft PC as described in Section 4-2.1,
use the web browser on the Craft PC to log into the Link CX built-in web server as follows:
8 Launch the web browser per the manufacturers instructions.
9 Open the web page at ethernet address 10.0.0.2 (transmit low models) or 10.0.0.3 (transmit
high models) in the web browser.
If the web browser ethernet address has been changed, use the replacement ethernet
address instead of 10.0.0.x..
10 If the Link CX has not been configured for a login and password, continue with Step 11. If
the Link CX has already been configured for a login and password, enter both and continue
with Step 11.
11 The web browser displays the Monitor Page, similar to the one shown in Figure 4-3. Note
that the values shown for each of the parameters will vary, depending on the state of the
Link CX.
Figure 4-2 Link CX Configuration Setup
IW093202
Craft PC
Mil-Type
Connector
CAT-5 Ethernet
Cable
RJ-45 Ethernet
Port
From +/-21 to
+/-60 Vdc Supply