User's Manual

Table Of Contents
Enterprise MIBs and Traps 117
A value of 1 indicates the Rx synthesizer is locked.
A value of 2 indicates the Rx synthesizer is unlocked"
::= }link_cx_status 6}
lowTxPowerAlarmStatus OBJECT-TYPE -- local alarm condition
SYNTAX INTEGER {
normal(1),
alarm(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A value of 1 indicates the Tx power at the antenna port
is greater than or equal to -14 dBm. A value of 2 indicates
the Tx power at the antenna port is less than -14 dBm."
::= }link_cx_status 7}
demodLockAlarmStatus OBJECT-TYPE -- link alarm condition
SYNTAX INTEGER {
normal(1),
alarm(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The demodulator lock status.
A value of 1 indicates the demodulator is locked.
A value of 2 indicates the demodulator is unlocked"
::= }link_cx_status 8}
lowRssiLevelAlarmStatus OBJECT-TYPE -- link alarm condition
SYNTAX INTEGER {
normal(1),
alarm(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A RSSI alarm will be generated if the level of RSSI goes below
the user configured RSSI alarm level, rfRssiAlarmThresholdSetting.
A value of 1 indicates the received signal level is above the RSSI
alarm threshold. A value of 2 indicates the received signal level
is at or below the user configured RSSI alarm level.
This alarm is valid only if the Rx synthesizer is locked."
::= }link_cx_status 9}
receiverOverloadAlarmStatus OBJECT-TYPE -- link alarm condition
SYNTAX INTEGER {
normal(1),
alarm(2)
}