User's Manual
Table Of Contents
- UltraWAVE BTS 6 Installation and Commissioning Guide
- One - Unpacking and Configuration Verification
- Two - Installation
- 2-1 Site Requirements
- 2-2 Mounting the BTS Chassis
- 2-3 Configuring the E1 or T1 Trunk Card
- 2-4 Connecting Power and Ground Cables
- 2-5 Connecting E1 or T1 Trunk Cables
- 2-6 Connecting Antennas
- 2-6.1 Omni 1 TRX (O1) Configuration
- 2-6.2 Omni 2 TRX (O2) Configuration
- 2-6.3 Omni 3 TRX (O3) Configuration
- 2-6.4 Omni 4 TRX (O4) Configuration
- 2-6.5 Omni 5 TRX (O5) Configuration
- 2-6.6 Omni 6 TRX (O6) Configuration
- 2-6.7 Omni 5 (05) and Omni 6 (O6) 25 Watt Configuration
- 2-6.8 Sectorized Two TRX (S11) Configuration
- 2-6.9 Sectorized Three TRX (S111) Configuration
- 2-6.10 Two Sector Four TRX (S22) Configuration
- 2-6.11 Three Sector Four TRX (S211) Configuration
- 2-6.12 Three Sector Five TRX (S221) Configuration
- 2-6.13 Three Sector Six TRX (S222) Configuration
- 2-6.14 Two Sector Five TRX (S32) Configuration
- 2-6.15 Two Sector Six TRX (S33) Configuration
- 2-6.16 Two Sector Six TRX (S42) Configuration
- 2-6.17 RF Radiation Hazard
- 2-7 Connecting External Alarms
- 2-8 Post Installation Cabling and Checks
- Three - Off-Line Commissioning
- 3-1 Pre Off-Line Commissioning
- 3-2 Off-Line Commissioning the UltraWAVE BTS
- 3-3 Software verification using Craft PC
- 3-3.1 Verifying the Current Software Version and Patch Level
- 3-3.2 Checking the Flash Version Number
- 3-3.3 Running E1 or T1 POST Diagnostics
- 3-3.4 Verifying Telnet Communications with the BTS over Ethernet
- 3-3.5 Running TRX POST Diagnostics
- 3-3.6 Reviewing POST Results
- 3-3.7 Rebooting the BTS after Running POST
- 3-3.8 Terminating Serial Communications with the BTS
- 3-4 Exiting XWindows on the Craft PC
- 3-5 Upgrading the BTS Software Version (Flash)
- 3-6 Post Off-Line Commissioning
- Four - Off-Line Commissioning of a Daisy Chain
- Five - On-Line Commissioning
- Checklist 1 - Site Readiness Checklist
- Checklist 2 - Installation Checklist
- Checklist 3 - Commissioning Checklist
80 UltraWAVE BTS Installation and Commissioning Guide, Release 6.5A
5 Make a call through the BTS. After the initial setup messages, the following log as described
in Figure 5-2 will be produced every five seconds for each call in progress. Figure 5-2 shows
what each set of bytes means. Note that all of the counters are either two or four bytes, in
twos complement.
The TRX and DSP numbers that are being used appear immediately to the left of the EVTI.
The “DSP count of bit errors” shows the bit errors estimated by the DSP in the uplink
direction, for every five seconds (250 speech frames). Under normal testing conditions
where the mobile is stable and reasonably close to the BTS, this value should remain 00
during testing. If the value is consistently high (that is, above 10) then it is recommended
that you perform a Racal test to determine the serviceability of the TRX.
6 Place calls through each TRX and DSP. To allocate calls to different TRXs and DSPs refer to
the procedure used in Section 5-2.
This estimate of BER is not 100% accurate, because a codeword after
data corruption can be mapped to another valid codeword, thus
undetected by the DSP error estimation mechanism of decoding,
re-encoding and bit-comparison.
Figure 5-2 Description of DSP Event Indication (EVTI) messages
EVTI(27,0c) 34 00 fa ff b2 00 fa 00 00 00 00 00 00 08 00 00 73 55 e0 00 03 2b 5e 35 ed 14 aa 00 00
uplink___^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^
underflow| | | | | | | | | | | | | |
| | | | | | | | | | | | |
disregard___| | | | | | | | | | | | |
this byte | | | | | | | | | | | |
| | | | | | | | | | | |
downlink _________| | | | | | | | | | | |
underflow | | | | | | | | | | |
| | | | | | | | | | |
accumulated timing_____| | | | | | | | | | |
offset | | | | | | | | | |
good speech frames__________| | | | | | | | | |
| | | | | | | | |
bad speech frames (BFI)____| | | | | | | | |
| | | | | | | |
# bad SACCHs_________________| | | | | | | |
| | | | | | |
# bad FACCHs_________________| | | | | | |
| | | | | |
DSP count of bit errors_______________| | | | | |
| | | | |
accumulated viterbi cost (4 bytes)_______________| | | | |
| | | |
accumulated eq quality (4 bytes)______________________| | | |
| | |
rx rssi_________________________________| | |
| |
rssi in log10_________________________| |
|
AGC Parameters__________________|