76 UltraWAVE BTS Installation and Commissioning Guide, Release 6.5A
Test 3
A If the second external alarm is used, close the alarm relay (i.e. trigger the second
customer-defined alarm).
B After a delay, the OMC operator must observe an alarm event.
C Close the alarm relay by opening the alarm contact.
D After a delay, the alarm state displayed at the OMC changes from open to closed.
TCH Timeslot Tests
1 In this test, the OMC operator unlocks individual TCH timeslots and the field technician
places a mobile-to-mobile call over each timeslot using a mobile handset in debug mode.
Refer to the documentation provided by the module handset manufacturer for the proper
procedures.
For each timeslot, the commissioner should verify that:
The timeslot displayed on the handset corresponds to the timeslot unlocked by the
OMC operator.
A two-way call is completed successfully.
The call has good audio quality and power, and low interference.
The number of timeslots to be tested differs depending on whether you have one, two or
three TRXs. Table 5-1 provides the sequence for 1 TRX, Table 5-2 provides the sequence
for 2 or more TRXs.
Table 5-1 Timeslots Needing Testing in a One-TRX BTS
TRX Number Timeslot Number Channel Type Testing Necessary
First TRX (TRX in Slot 6)
0 BCCH Combined No
1 TCH Yes
2 TCH Yes
3 TCH Yes
4 TCH Yes
5 TCH Yes
6 TCH Yes
7 TCH Yes
Note: To run an abbreviated version of this test, test any one of timeslots 0-3 and of
timeslots 4-7 on each TRX.