User's Manual
Table Of Contents
- UltraWAVE BTS 6 Installation and Commissioning Guide
- One - Unpacking and Configuration Verification
- Two - Installation
- 2-1 Site Requirements
- 2-2 Mounting the BTS Chassis
- 2-3 Configuring the E1 or T1 Trunk Card
- 2-4 Connecting Power and Ground Cables
- 2-5 Connecting E1 or T1 Trunk Cables
- 2-6 Connecting Antennas
- 2-6.1 Omni 1 TRX (O1) Configuration
- 2-6.2 Omni 2 TRX (O2) Configuration
- 2-6.3 Omni 3 TRX (O3) Configuration
- 2-6.4 Omni 4 TRX (O4) Configuration
- 2-6.5 Omni 5 TRX (O5) Configuration
- 2-6.6 Omni 6 TRX (O6) Configuration
- 2-6.7 Omni 5 (05) and Omni 6 (O6) 25 Watt Configuration
- 2-6.8 Sectorized Two TRX (S11) Configuration
- 2-6.9 Sectorized Three TRX (S111) Configuration
- 2-6.10 Two Sector Four TRX (S22) Configuration
- 2-6.11 Three Sector Four TRX (S211) Configuration
- 2-6.12 Three Sector Five TRX (S221) Configuration
- 2-6.13 Three Sector Six TRX (S222) Configuration
- 2-6.14 Two Sector Five TRX (S32) Configuration
- 2-6.15 Two Sector Six TRX (S33) Configuration
- 2-6.16 Two Sector Six TRX (S42) Configuration
- 2-6.17 RF Radiation Hazard
- 2-7 Connecting External Alarms
- 2-8 Post Installation Cabling and Checks
- Three - Off-Line Commissioning
- 3-1 Pre Off-Line Commissioning
- 3-2 Off-Line Commissioning the UltraWAVE BTS
- 3-3 Software verification using Craft PC
- 3-3.1 Verifying the Current Software Version and Patch Level
- 3-3.2 Checking the Flash Version Number
- 3-3.3 Running E1 or T1 POST Diagnostics
- 3-3.4 Verifying Telnet Communications with the BTS over Ethernet
- 3-3.5 Running TRX POST Diagnostics
- 3-3.6 Reviewing POST Results
- 3-3.7 Rebooting the BTS after Running POST
- 3-3.8 Terminating Serial Communications with the BTS
- 3-4 Exiting XWindows on the Craft PC
- 3-5 Upgrading the BTS Software Version (Flash)
- 3-6 Post Off-Line Commissioning
- Four - Off-Line Commissioning of a Daisy Chain
- Five - On-Line Commissioning
- Checklist 1 - Site Readiness Checklist
- Checklist 2 - Installation Checklist
- Checklist 3 - Commissioning Checklist
72 UltraWAVE BTS Installation and Commissioning Guide, Release 6.5A
5-1 Pre On-Line Commissioning Requirements
Before on-line commissioning begins, the field technician or the OMC operator must verify that:
• The BSC or BS Plus, and the WXC or MSC are fully commissioned, in service and connected
to each other and to the BTS.
• The OMC is in service and connected to the BSC via the MSC as defined in the interWAVE
Network Implementation Manual.
• The database questionnaire is completed, with all necessary BTS parameters listed, as
defined in the interWAVE Network Implementation Manual
.
• The OMC operator has successfully created and configured the BTS object on the OMC and
downloaded this information to the BTS.
• The RF frequencies are cleared to transmit.
• The E1 or T1 connection between the BTS and the BSC has been commissioned.
• The BSC-BTS E1 or T1 link is properly certified. Note that the certification should state
length of testing and BER results.
• The HLR subscriber data has been entered into the HLR using the Subscriber Management
GUI, as described in the interWAVE Subscriber Management Guide
. In particular, the HLR
must be configured to support the SIM cards of the mobiles used by the field technician.
• The Abis link and its child objects are locked at the OMC.
Once the E1 or T1 link has been properly connected to the BTS E1 or T1
trunk card, both port alarm LEDs for the connected port should turn off.
If one or both LEDs remain lit, signifies an E1 or T1 link problem related
to either a faulty connector or the E1 or T1 link itself. Refer to the
interWAVE Field Maintenance Guide
for additional information.
It is the operator's responsibility to verify that all BSC-BTS E1 or T1 Abis
links are ordered, installed and certified by the local telephone provider.
Certification should include a bit error ratio/rate test of at least
20 minutes on the Abis interface, with a BER of 10
-8
or better.