User's Manual

Table Of Contents
64 UltraWAVE BTS Installation and Commissioning Guide, Release 6.5A
3-3.7 Rebooting the BTS after Running POST
1 Type:
bts-> reboot [ENTER]
This action places the TRX in an on-line and operational state.
2 Reconnect all E1 or T1 lines to the BTS.
3-3.8 Terminating Serial Communications with the BTS
bts:> postReportE1Trx
******************* E1 DIAGNOSTICS REPORT *******************
*************************************************************
Slot:1
E1(1)TID01: Initialize Peripheral Registers : PASS
E1(1)TID02: Peripheral Register Test : PASS
E1(1)TID03: Framer Register Test : PASS
E1(1)TID04: VME to CPU FIFO Flag Test : PASS
E1(1)TID05:Initialize Time/Space sw Chip : PASS
E1(1)TID06: Software Download Test : Not-Run
E1(1)TID07: Memory Test : Not-Run
E1(1)TID08: CPM download Test : Not-Run
E1(1)TID09: TRAU DSP Test : Not-Run
E1(1)TID10: Cross Connect Test : Not-Run
*************************************************************
******************* TRX DIAGNOSTICS REPORT ******************
*************************************************************
Slot 6
-------------------------------------------------------------
All Tests PASSED
*************************************************************
value=58=0x3a='="
bts:>
Figure 3-10 Reviewing E1 or T1 and TRX POST Results
There are five tests that are not run but show up in the results section
when the user manually retrieves the POST results. These tests are not
displayed when running POST by rebooting the BTS. They are:
T1(1) TID06: Software Download Test : Not-Run
T1(1) TID07: Memory Test : Not-Run
T1(1) TID08: CPM Download Test : Not-Run
T1(1) TID09: TRAU DSP Test: Not-Run
T1(1) TID10: Cross Connect Test: Not-Run
If you are going to perform the Racal tests described in the interWAVE
Radio Test Manual at this time, ensure that you have rebooted the
chassis. Also, leave the Craft PC connected to the IWP card and a serial
communications session active.