User's Manual

Table Of Contents
Off-Line Commissioning 59
The ICP configuration states Current Image = N where N is either 0 or 1. The flash version have
lines in the format:
iw06_05.ZZZ
where iw06_05.ZZZ indicates the flash version.
The flash version number should be iw06_05.012 or higher for BTS TRX POST diagnostics to be able to
run. If it is not, the flash version number will have to be changed and the BTS rebooted. To do this, refer
to Section 3-5.
3-3.3 Running E1 or T1 POST Diagnostics
1 Disconnect all E1 and/or T1 lines from the BTS. This ensures that no Abis connection exists.
If an Abis connection does exist, the TRX POST might not run properly.
2 Wait until the
bts-> prompt appears, and type:
bts-> reboot [ENTER]
**** Current Image = 1 ****
******** Image 0 *********
Image IW version : iw06_05.011
Image creation date: 04/15/02 13:44
Image crc : 1ff03d8d
******** Image 1 *********
Image IW version : iw06_05.012
Image creation date: 04/09/02 12:07
Image crc : e3b05e8c
******** Image 2 *********
Image IW version : iw06_00.028
Image creation date: 04/09/02 12:07
Image crc : e3b05e8c
Figure 3-7 Determining the Flash Version on ICP Processor Card
Flash Image 2 is reserved for interWAVE Customer Service use ONLY.