User's Manual

Table Of Contents
58 UltraWAVE BTS Installation and Commissioning Guide, Release 6.5A
3-3 Software verification using Craft PC
In this section, you use the Craft PC to verify the software configuration and other aspects of the BTS
operation. The first sections describe how to connect and start the Craft PC; subsequent sections
provide necessary test and verification procedures.
3-3.1 Verifying the Current Software Version and Patch Level
1 If not already done, establish serial communications with the BTS as described in
Section 3-2.4.
2 If you have not already done so, reboot the chassis by pressing the key combination
[CTRL][x]. If you do not receive a prompt after reboot, press [ENTER] to display the
bts-> prompt.
3 After the
bts-> prompt appears, verify the current software version and patch level by
typing:
bts-> iwversion [ENTER]
BTS code version: iw06_05.ZZZ
Release number: 6.5
ABIS version: 1.1
The current software version is displayed, represented above by the parameter
iw06_05.ZZZ. This number should correspond to the software version detailed in the
release notes included with the CD-ROM. Keep this number for your records.
4 Verify under
Patches Installed: that the most current patch is installed, if applicable.
Refer to the interWAVE Craft PC Guide
for procedures to install required patches. If you are
unsure if you require software patches, contact your Level
2 support representative for addi-
tional assistance.
3-3.2 Checking the Flash Version Number
In order to verify that the correct software build is loaded into flash memory, go to your serial Xterm
window and type:
bts-> printConfigBlocks [ENTER]
Figure 3-7 shows Image 0 and Image 1 from the ICP card configuration.
For more information about the Craft PC, refer to the interWAVE Craft
PC Guide.