User's Manual

Table Of Contents
16 UltraWAVE BTS Installation and Commissioning Guide, Release 6.5A
Required Materials
Angle brackets
Four M10 machine screws and washers
Required Tools
15 mm open end wrench
Installation Instructions
1 Move the cabinet into its final location. If using alignment pins to prevent movement, move
the cabinet into position over the pins.
2 Lower the each of the rubber feet until each reaches the concrete pad.
3 Using the 15 mm open end wrench, lower each foot until the casters are raised from the
concrete floor, approximately 0.25 in. (0.65 cm).
4 Remove the casters from the bottom of the cabinet.
5 Lower the cabinet to within 4.1 in. to 4.4 in. (10.41 cm to 11.18 cm) of the concrete pad. If
you are using alignment pins, lower the cabinet until the pins should enter the alignment
holes no more than 0.25 in. (0.6 cm). Do not lower the cabinet too far over alignment pins
as they may puncture internal components.
6 Secure locking nuts on foot studs.
7 Secure the cabinet using customer-provided 10 mm studs.
Rack Mount Advisory
To prevent bodily injury when mounting or servicing this unit in a rack, you must take special
precautions to ensure that the system remains stable. The following guidelines are provided to ensure
your safety:
This unit should be mounted at the bottom of the rack if it is the only unit in the rack.
When mounting this unit in a partially filled rack, load the rack from the bottom to the top
with the heaviest component at the bottom of the rack.
If the rack is provided with stabilizing devices, install the stabilizers before mounting or
servicing the unit in the rack.
Attention: Pour éviter toute blessure corporelle pendant les opérations de montage ou de réparation de
cette unité en casier, il convient de prendre des précautions spéciales afin de maintenir la stabilité du
système. Les directives ci-dessous sont destinées à assurer la protection du personnel :
Si cette unité constitue la seule unité montée en casier, elle doit être placée dans le bas.
You may use the additional M10 tap holes to secure the cabinet as
site-specific conditions allow.