User's Manual
Table Of Contents
- UltraWAVE Micro BTS Installation and Commissioning Guide
- Chapter 1 - Unpacking and Configuration Verification
- Chapter 2 - Installation
- 2.1 Analyzing Site Requirements
- 2.2 Mounting the Micro BTS Chassis
- 2.3 Configuring the E1 or T1 Trunk Card
- 2.4 Connecting Ground Cables
- 2.5 Connecting Power Supplies
- 2.6 Connecting E1 or T1 Trunk Cables
- 2.7 Connecting Antennas
- 2.8 Connecting External Alarms
- 2.9 Making a Serial Connection to the Processor Card
- 2.10 Network Connections
- 2.11 Post Installation Cabling and Checks
- Chapter 3 - Off-Line Commissioning
- 3.1 Pre Off-Line Commissioning
- 3.2 Off-Line Commissioning of the Micro BTS
- 3.2.1 Starting XWindows Using the Craft PC
- 3.2.2 Connecting the Craft PC to the ICP Processor Card
- 3.2.3 Setting Up a Serial Connection via the ICP Processor Card Serial Port
- 3.2.4 Power-On LED Tests
- 3.2.5 Configuring Boot Parameters
- 3.2.6 Setting Up an Ethernet Connection to the ICP Processor Card Ethernet Port
- 3.2.7 Verifying Telnet Communications with the Micro BTS over Ethernet
- 3.3 Software Verification using Craft PC
- 3.3.1 Verifying the Current Software Version and Patch Level
- 3.3.2 Checking the Flash Version Number
- 3.3.3 Running E1 or T1 POST Diagnostics
- 3.3.4 Running TRX POST Diagnostics
- 3.3.5 Reviewing POST Results
- 3.3.6 Rebooting the Micro BTS after Running POST
- 3.3.7 Terminating Serial Communications with the Micro BTS
- 3.3.8 Exiting XWindows on the Craft PC
- 3.4 Upgrading the Micro BTS Software Version (Flash)
- 3.5 Post Off-Line Commissioning
- Chapter 4 - Off-Line Commissioning of a Daisy Chain
- Chapter 5 - On-Line Commissioning
- Checklist 1 - Site Readiness Checklist
- Checklist 2 - Installation Checklist
- Checklist 3 - Commissioning Checklist
- Index
48 UltraWAVE Micro BTS Installation and Commissioning Guide, Version B
Chapter 2 - Installation
Conversion Cables
If you are connecting into an existing E1 network with standard BNC or DSUB
connectors, a conversion cable for either the 75 Ohm or 120 Ohm will be required.
To purchase these cables from Alvarion, contact your local sales support
representative.
Figure 2-18 illustrates the pinout for an RJ-48C to 75 Ohm BNC conversion cable.
Table 2-10: Customer-Supplied E1 Cabling
Cable Identity Cable Type Corresponding Cable Plug
E1, 120 Ohm Shielded, Twisted, 2-Pair RJ-48C Male
E1, 75 Ohm Coaxial RJ-48C Male
Antenna (external) Coaxial N-Type, Female
Note: The number of cables required depends on the ordered configuration of the
Micro BTS.
Figure 2-18: 75 Ohm BNC Conversion Cable
IW009302
8
ORANGE/WHITE
BLUE/WHITE
WHITE/ORANGE
WHITE/BLUE (R-TIP)
(R-RING)
(T-TIP)
(T-RING)
1
2
3
5
6
7
4
J2
J3
J1
J2
J3
RECEIVE
TRANSMIT
Pin 1
Pin 8
J1