User's Manual

Table Of Contents
UltraWAVE Micro BTS Installation and Commissioning Guide, Version B 87
Software Verification using Craft PC
The format for each diagnostic line is:
[line number][action][TRX number][test number][test description]
[test result]
For example:
14 (Diag) ISR(2) TF22: Test Basic op of VME/RTP FIFOs: PASSED
where:
Figure 3-9 shows the TRX POST results for a TRX in slot 2 of the Micro BTS and
shows that the TRX POST diagnostics ran successfully on the TRX card.
Table 3-3: Description of the TRX POST Results
Line Entry Description
14 Line number
Diag Diagnostic test being run
ISR(2) ISR TRX 2 is being tested
TF22 Test number
Test Basic op of VME/RTP FIFOs Test description
PASSED Indicates that the TRX passed this test
SerialNumber: 16 (txpostf) STARTING BTS FUNCTIONAL CODE...
a3 a8 0 0 1 0 20 4a
SerialNumber: a3 28 0 0 1 0 20 a0
SerialNumber: a3 2d 0 0 1 0 20 4b
SerialNumber: a3 50 1 0 1 0 20 54
SerialNumber: a3 95 0 0 1 0 20 ed
SerialNumber: a3 a9 0 0 1 0 20 7d
17 (Diag ) TRX CARD IN SLOT 2 : STARTING TRX POST OFFLINE Test
18 (Diag ) ISR(2) tf 5 Test VME Access ....................... PASSED
19 (Diag ) ISR(2) tf 12 Load FPGA (TDM) ....................... PASSED
20 (Diag ) ISR(2) tf 13 Load FPGA (RC) ........................ PASSED
21 (Diag ) ISR(2) tf 16 Load DSP (Coder) ...................... PASSED
22 (Diag ) ISR(2) tf 17 Load DSP (Equalizer) .................. PASSED
23 (Diag ) ISR(2) tf 18 Load DSP (Modulator) .................. PASSED
24 (Diag ) ISR(2) tf 19 Ping DSP (Coder) ...................... PASSED
25 (Diag ) ISR(2) tf 20 Ping DSP (Equalizer) .................. PASSED
26 (Diag ) ISR(2) tf 46 Ping DSP (Modulator) .................. PASSED
27 (Diag ) ISR(2) tf 22 DSP Diag Mode ON (Coder) .............. PASSED
28 (Diag ) ISR(2) tf 27 Test External RAM (Coder) ............. PASSED
29 (Diag ) ISR(2) tf 24 DSP Diag Mode ON (Equalizer) .......... PASSED
30 (Diag ) ISR(2) tf 28 Test External RAM (Equalizer) ......... PASSED
31 (Diag ) ISR(2) tf 47 Test Mdltr DSP Serial Bus loopback .... PASSED
32 (Diag ) ISR(2) tf 30 Test TDM Control Store RAM ............ PASSED
33 (Diag ) ISR(2) tf 34vvvvvvvvvvvvTest TDM Loop-back .................... PASSED
34 (Diag ) ISR(2) tf 36 Test RC to Equalizer Serial Bus ....... PASSED
35 (Diag ) ISR(2) tf 39 Test Coder to RC Serial Bus ........... PASSED
36 (Diag ) ISR(2) tf 40 Test Equalizer To Coder Serial Bus .... PASSED
37 (Diag ) ISR(2) tf 43 Test Tuner Register Read/Write ........ PASSED
lowChannel = 128, highChannel = 251
38 (Diag ) ISR(2) tf 41 Test Channel Synthesizers ............. PASSED
39 (Diag ) ISR(2) tf 48 Test Power Ramp External RAM .......... PASSED
40 (Diag ) ISR CARD IN SLOT 2 : COMPLETED POST OFFLINE Test : PASSED
Figure 3-9: TRX POST Results