84 UltraWAVE Micro BTS Installation and Commissioning Guide, Version B
Chapter 3 - Off-Line Commissioning
3.3.2 Checking the Flash Version Number
In order to verify that the correct software build is loaded into flash memory, go to
your serial Xterm window and type:
bts-> printConfigBlocks [ENTER]
The screen displays information relating to the flash images. Figure 3-7 shows
Image 0, Image 1 and Image 2 from the ICP card configuration.
The ICP configuration states Current Image = N where N is either 0 or 1. The
flash version have lines in the format:
iw07_00.ZZZ
where iw07_00.ZZZ indicates the flash version.
If the displayed software version number does not coincide with
the software version being run on the network for which this
Micro BTS is going to be used, refer to Section 3.4 for
instructions on how to install a different software version on the
processor card.
**** Current Image = 1 ****
******** Image 0 *********
Image IW version : iw07_00.010
Image creation date: 04/15/02 13:44
Image crc : 1ff03d8d
******** Image 1 *********
Image IW version : iw7_00.012
Image creation date: 04/09/02 12:07
Image crc : e3b05e8c
******** Image 2 *********
Image IW version : iw07_00.010
Image creation date: 04/09/02 12:07
Image crc : e3b05e8c
Figure 3-7: Determining the Flash Version on an ICP Processor Card