Specifications

Reference Guide
A-9
A.3.2 Chassis Power
A.3.3 Environment
A.3.3.1 Ambient Temperature and Humidity
Ambient temperature and humidity as per GR-63-CORE R4-6 and R4-7.
Ambient refers to conditions at a location 1.5 m (59 in) above the floor and 400 mm (15.8 in)
in front of the equipment. Short-term refers to a period of not more than 96 consecutive hours
and a total of not more than 15 days in 1year. This refers to a total of 360 hours in any given
year, but, no more than 15 occurrences during that 1 year period.
A.3.3.2 Altitude
As per GR-63-CORE R4-8. Functional within the limits specified in the table above when
installed at elevations between 60 m (197 ft.) below sea level and 1800 m (5905 ft.) above sea
level. As per O4-10. Functional within the limits specified in the table above when installed
at elevations between 1800 m (5905 ft.) and 4000 m (13,123 ft.) above sea level.
Chassis Description
Model
Number
AC Power (50-60 Hz) DC Power
Power
Consumption
110 VAC 220 VAC -48 VDC 24 VDC Watts
600 Chassis with Installation
Kit Steel Chassis, Front
Loading, “V” Steel Card
Guides, CE Marked
891630 90 VAC
to 135
VAC
175 VAC
to 264
VA C
-40 VDC
to -60
VDC
+18 VDC
to 35
VDC
125 (typical)
300 W
(maximum)
800 Chassis with Installation
Kit, Steel Chassis, Front and
Rear Loading, “V” Steel Card
Guides, CE Marked
891830 90 VAC
to 135
VAC
175 VAC
to 264
VA C
-40 VDC
to -60
VDC
+18 VDC
to 35
VDC
125 (typical)
300 W
(maximum)
900 Chassis with Installation
Kit, Power-Enhanced, Steel
Chassis, Top and Bottom
Front Loading, “V” Steel
Card Guides, CE Marked
891930 115 VAC
104 to
135 VAC
175 VAC
to 264
VA C
-40 VDC
to -60
VDC
+18 VDC
to 35
VDC
125 (typical)
500 W
(maximum)
Temperature
o
C /
o
F Humidity
Operate Short Term Storage Operate Short Term
0 to 50
o
C
32 to 122
o
F
-5 to 50
o
C
23 to 122
o
F
-20 to 80
o
C
-4 to 176
o
F
50 to 95% relative
humidity, non
condensing
5 - 90 (not to exceed
0.024 kb H
2
O/kg dry
air)
Rate of temperature change
30
o
C/hr (54
o
F/hr)