Specifications
Reference Guide
7-57
WAN Card WAN Card User Screens and Settings
Table 7-20. PairGain T1/HDSL Module Screen Actions
Table 7-21. PairGain T1/HDSL Module Screen Option Settings and Defaults
Action Function
Save Saves changes to settings.
Undo Returns all settings to the last saved state.
Refresh Redraws the screen.
Clear Clears 24Hr ES and 24HR UAS
Main Returns to the WAN Card Main Screen.
Parameter User Options Default
CIRCUIT ID
Any combination of letters or numbers
up to 24 characters, including spaces
************************
TRAIN MODE slave master slave
LOOPBACK none nloc crem cloc nrem cdul cdu2
ndu1 ndu2
none
LB TIMEOUT no to 20 m 60 m 120 m no to
FRAMING auto_detect unframed auto_detect
LINE CODE auto_detect b8zs ami auto_detect
ALARMS R:Slve ChR 1:DBL1 ChR 2:DBL2 ChR
M:Mstr Fail S:Slve Fail N:No Sync
N:No Sync
LB STATE read-only read-only
*LOCAL*
SNR LOOP 1,2
PLS ATTN 1,2
24Hr ES 1,2
24Hr UAS 1,2
read-only read-only
*REMOTE*
SNR LOOP 1,2
PLS ATTN 1,2
24Hr ES 1,2
24Hr UAS 1,2
read-only read-only