Specifications
7-52
Reference Guide
Model No.
Running Head
WAN Card User Screens and Settings WAN Card
Table 7-17. Adtran E1/HDSL Screen Actions
Table 7-18. Adtran E1/HDSL Screen Option Settings and Defaults
TRAIN MODE
This parameter determines the master/slave relationship between the units. The setting for the
central office master unit is
ltu
(default). Remote slave units should be set to
ntu
.
LOOP
This parameter sets loopbacks on the remote unit. Selecting
r-loc
will cause the remote link
to loop back to the PCM buses of the remote unit. Selecting
r-net
will cause the remote link
to loop back to the network. The default is
off
.
LOSS LP1
This number indicates the loss in loop 1 within
±
2 dB.
LOSS LP2
This number indicates the loss in loop 2 within
±
2 dB.
Action Function
Save Saves changes to settings.
Undo Returns all settings to the last saved state.
Refresh Redraws the screen.
Perf Brings up the HDSL Performance Data Screen (refer to HDSL section)
Main Returns to the WAN Card Main Screen.
Parameter User Options Default
TRAIN MODE ltu ntu ltu
LOOP off r-loc r-net off
LOSS LP 1 no user input display only
LOSS LP 2 no user input display only
QLTY LP 1 no user input display only
QLTY LP 2 no user input display only
LP STATUS no user input display only