Specifications
Reference Guide
4-89
System Configuration and Operation Checking the Time Slot Map
For E1 transmission (Figure 4-61), time slot 0 and 16 are not available for assignment on
either the HSU table or the voice card time slots.
Like T1 operation in
d/i
mode, unspecified
time slots are
automatically
assigned to corresponding slots on the other WAN port on the
same card.
Figure 4-61. Typical Time Slot Screen in E1 Operation
Node_1 | W1 CEPT+CEPT Rev A6-2 Ser 00101 | 12-31-99 14:33
TS XCON TS CIRCUIT_ID TS XCON TS CIRCUIT_ID
0 frame align 64k 16 cas 64k
1 U5-1 A-01 user_circuit 17 U7-1 A-17 user_circuit
2 U5-2 A-02 user_circuit 18 U7-2 A-18 user_circuit
3 U5-3 A-03 user_circuit 19 U7-3 A-19 user_circuit
4 U5-4 A-04 user_circuit 20 U7-4 A-20 user_circuit
5 U5-5 A-05 user_circuit 21 U7-5 A-21 user_circuit
6 U5-6 A-06 user_circuit 22 U7-6 A-22 user_circuit
7 U5-7 A-07 user_circuit 23 U7-7 A-23 user_circuit
8 U5-8 A-08 user_circuit 24 U7-8 A-24 user_circuit
9 U6-1 A-09 user_circuit 25 U8-1 A-25 user_circuit
10 U6-2 A-10 user_circuit 26 U8-2 A-26 user_circuit
11 U6-3 A-11 user_circuit 27 U8-3 A-27 user_circuit
12 U6-4 A-12 user_circuit 28 U8-4 A-28 user_circuit
13 U6-5 A-13 user_circuit 29 U8-5 A-29 user_circuit
14 U6-6 A-14 user_circuit 30 U8-6 A-30 user_circuit
15 U6-7 A-15 user_circuit 31 U8-7 A-31 user_circuit
Refresh | Test | Main