4.21.4 Monitor Circuit
With the monitor circuit, the data test center (by remote access) creates a “hitless” monitor
connection (i.e.,one that can be created, maintained and dropped without affecting the
information on the circuit being tested) between the data test center and the Node_1 Device.
Highlighting the desired circuit and pressing the “N” key brings up the add monitor circuit
screen shown in Figure 4-53.
Figure 4-53. The Add Monitor Circuit Screen
Cross connect information is added in a similar fashion to the Add Broadcast screen
mentioned previously. Figure 4-54 shows the completed monitor circuit.
Node_1 | C1 10161 CPU XCON COM 407535038 Ser 00101 | 12-31-99 14:33
page: 1 of 1
CIRCUIT ID FACILITY TEST EQUIPMENT TEST TYPE TC CNV
Jacksonville w1-1 01*64 off w1-2 01*64 off d moos n/a
new_circuit w1-1 00*64 off w1-1 00*64 off m/d moos n/a
moNitor | spLit | Release | Tla | pgUp | pgDn | Main