Specifications
4-22
Reference Guide
Model No.
Running Head
Alarms System Configuration and Operation
4.7.2 Alarm Filter Settings
You can set filters for each alarm so that the alarm reports occurrences in a number of different
ways. Figure 4-13 shows the Alarm Filters screen, which is accessed by pressing "
f
" (
Filters
command) on the Alarm Screen.
Figure 4-13. Alarm Filters Screen
The first column of the Alarm Filters Screen is the alarm abbreviation that appears when an
alarm is generated. The second column is the associated full name of each alarm. Table 4-3
describes each alarm appearing in the Alarm Filters Screen.
The third column contains the filters
ignore
,
log
,
and
report
. Set the filter to
ignore
if you
want the system to ignore the alarm. Or, set it to
log
if you want the system to show the alarm
report on the screen and also log it into the Alarm History, as described later in this chapter.
Set the filter to
report
if you want the system to send (report) the alarm indication to a remote
device. With this setting, the system will also display the alarm report on the screen and log it
into the Alarm History.
Node_1 | | 12-31-99 14:33
OOS Out of Service report crit aco-on
NOS No Signal report major aco-off
LOS Loss of Sync report minor aco-off
YEL Yellow Alarm report info aco-off
AIS Alarm Info Signal report crit aco-off
CGA_RED Carrier Group–Red report crit aco-off
CGA_YEL Carrier Group–Yellow report crit aco-off
EER Excessive Error Rate report crit aco-off
SENSOR Alarm card sensor report crit aco-off
DCHAN D-chan out of service report crit aco-off
SWITCH Switch to redundant card report crit aco-off
UCA User card/port alarm report crit aco-off
RESET System reset report crit aco-off
ACO Alarm Cut-Off report crit n/a
SYNC Clock Sync Alarm report crit aco-off
EER-3 Error rate above 10e-3 report crit aco-off
PLC_OOF DS3 PCLP Out of Framing report crit aco-off
PLC_LOF DS3 PCLP Losst of Frame report crit aco-off
PLC_YEL DS3 PCLP Yellow Alarm report crit aco-off
BP_OOS Back Plane Out of Service report crit aco-off