6. Front panel connections
6.1. Cat5 Connection 1
Cat5 cable carrying ADAT connections 1-4. Jacks “A” and “B” are electrically paralleled.
Depending on the number of jacks used, the push button “Termination” has to be set:
1 cable = “ON”, 2 cables = “OFF”. See also 8.1. Cat5 Termination.
NOTE: Redundant connections (the connection of two units with two cables over A and B at the
same time) are not supported! This would lead to signal loops causing undefined current flow.
6.2. Cat5 Connection 2 (ADX-64A-PRO only)
Cat5 cable carrying ADAT connections 5-8 and the wordclock signal. Jacks “A” and “B” are
electrically paralleled. Depending on the number of jacks used, the push button “Termination”
has to be set: 1 cable = “ON”, 2 cables = “OFF”. See also 8.1. Cat5 Termination .