User`s manual
ADX-32A / ADX-64A-PRO
11. Settings overview
Switch location Label Function ON
(upper position)
OFF
(lower position)
Front panel
“Cat5 Connection 1”
Termination Cat5 cable
termination
One cable connected to
“Cat5 Connection 1”
Two cables connected to
“Cat5 Connection 1”
Front panel (*)
“Cat5 Connection 2”
Termination Cat5 cable
termination
One cable connected to
“Cat5 Connection 2”
Two cables connected to
“Cat5 Connection 2”
Rear panel
ADAT 1-4
1 ADAT 1 direction Output Input
(Output acts as loopback)
2 ADAT 2 direction Output Input
(Output acts as loopback)
3 ADAT 3 direction Output Input
(Output acts as loopback)
4 ADAT 4 direction Output Input
(Output acts as loopback)
5 No function
6 No function
Rear panel
ADAT 5-8/WC (*)
1 ADAT 5/Wordclock
direction
Output Input (Output acts as
loopback in ADAT mode)
2 ADAT 6 direction Output Input
(Output acts as loopback)
3 ADAT 7 direction Output Input
(Output acts as loopback)
4 ADAT 8 direction Output Input
(Output acts as loopback)
5 Wordclock
termination
75 ohms termination
active
No termination
6 Channel 5 mode ADAT 5
(Wordclock disabled)
Wordclock
(ADAT 5 disabled)
(*) ADX-64A-PRO model only
17