User`s manual
User's Manual
6. REAR PANEL
6.1. POWER Connections
PRIMARY
POWER
12V/1A
SECONDARY
POWER
12V/1A
Connect the supplied DC adapter(s) here. The Input “SECONDARY POWER” is only present on the ADX-64B-
PRO with the “Redundant Power Supply” option installed.
When the “Redundant Power Supply” option is installed, two DC adapters can be plugged into “PRIMARY
POWER” and “SECONDARY POWER”. If one of them fails, the other one takes over. This is particularly useful
to make the system immune to failure of a single AC phase in 3-phase supplies.
The status of the respective supply is shown on the corresponding front panel “Power” LEDs.
Without “Redundant power supply”, the “Cat5 connection 2” bank in the ADX-64B-PRO version is supplied
from the first bank. Both LEDs are constantly lit.
Use only the supplied DC adapter, or a replacement with the indicated voltage, power, polarity and matching
connector (see 12. Specifications). The input has a reverse-polarity protection.
If the Power LED does not go on when a DC adapter is connected, check the polarity.
6.2. ADAT 1-4
The transmission direction (TX or RX) must be set using the DIP switches 1-4:
Input (DIP switch in lower position = OFF): The ADAT connection is configured as input,
the received data is sent to the Cat5 cable.
The input signal is passed-through to the output alongside ("local loop-back"). You can use this
output to connect additional monitors or as wordclock source, as shown in7.2. Synchronization
over ADAT.
If you're using a daisy-chain of ADX devices, make sure that there is exactly one “Input” per ADAT connection
in the chain.
Output (DIP switch in upper position = ON): The ADAT connection is configured as output.
Data received from the Cat5 cable is output on the “Output” jack. The input jack is inactive.
8
1 2 3 4
5 6
ON
Cat5 Connection 1
1
IN OUT/THRU
MIDI1
IN
OUT/THRU IN OUT/THRU IN OUT/THRU IN OUT/THRU
2
3
4
OUT CH1
OUT CH2
OUT CH3
OUT CH4
IN
IN
IN
IN