User`s guide
ADASH Ltd. Adash 3600-MAIN-COM-PWR
ADASH Ltd., Czech republic, tel.: +420 596 232 670, fax: +420 596 232 671, email: info@adash.cz
For next technical and contact information visit www.adash.net, www.adash.cz
6
Terminal Board of the Adash 3600-COM Module
Fig. Terminal board of the Adash 3600-COM module
The display of the terminal board corresponds to the front view of the module.
Description of Terminal Connectors
POWER supply voltage (terminal connectors with the same marking are interconnected inside):
VCC +5 V / max. 50 mA,
GND 0 V.
RS-485 communication connection for the Adash 3600 system (terminal connectors with the
same marking are interconnected inside):
485-A signal A of RS-485,
485-B signal B of RS-485,
485-AR termination resistance 120R, for the termination of the interface to connect to terminal
connector 485-B.
ANALOG interconnection of the analogue output of the MAIN module with the BNC connector of
the COM module:
-AC external contact of the BNC connector,
+AC internal contact of the BNC connector,
GND 0 V, non-used.
RS-232 signals for continuous communication on RS-232:
232-GND common potential (ground),
232-RXD data reception,
232-TXD data transmission,
232-MOD do not connect!,
232-CTS ready for reception,
232-RTS transmission released.