User`s guide
ADASH Ltd. Adash 3600-MAIN-COM-PWR
ADASH Ltd., Czech republic, tel.: +420 596 232 670, fax: +420 596 232 671, email: info@adash.cz
For next technical and contact information visit www.adash.net, www.adash.cz
4
Terminal Board of the Adash 3600-MAIN
Module
Fig. Terminal board of the Adash 3600-MAIN module
The display of the terminal board corresponds to the front view of the module.
Description of Terminal Connectors
POWER supply voltage:
VCC +5 V / 0.5 A,
GND 0 V.
SIGNAL connection of vibration sensor (or OUT output of the Adash 3600-MPX module):
SHLD vibration sensor cable shield,
+ICP vibration sensor ICP input, positive pole, or +OUT output of Adash 3600-MPX,
-ICP vibration sensor ICP input, negative pole, or -OUT output of Adash 3600-MPX.
DC IN DC input (temperature, pressure, ...):
+DC DC input positive pole,
-DC DC input negative pole.
AC OUT direct-current separated signal output from the connected vibration sensor:
AC OUT AC signal,
AC GND 0 V of the signal.
RS-485 communication connection for the Adash 3600 system:
485-A signal A of RS-485,
485-B signal B of RS-485,
485-AR termination resistance 120R, for the termination of the interface to connect to terminal
connector 485-B.