User`s guide

ADASH Ltd. Adash 3600-MAIN-COM-PWR
ADASH Ltd., Czech republic, tel.: +420 596 232 670, fax: +420 596 232 671, email: info@adash.cz
For next technical and contact information visit www.adash.net, www.adash.cz
18
5. Connection of the vibration sensor.
To connect the vibration sensor with ICP supply to the Adash 3600-MAIN unit, a special shielded
twisted cable is supplied, which is marked and connected as follows:
Conductor Sensor Module
colour terminal connector terminal connector
----------------------------------------------------------------------------------
Shield (braiding) - SHLD
White A +ICP
White / blue (black) B - ICP
Fig. Connection of the vibration sensor
6. Connection of mains power supply.
The terminal connectors for mains voltage supply for the entire set are located at the 3600-PWR
module and are indicated L (phase conductor) and N (neutral working conductor).
Supply terminal connectors
Fig. Position of terminal connectors 230 V
7. Replace the terminal connector covers.
The interconnection of the basic Adash 3600 set modules is completed and the system is ready for
configuration and measurement.