Setting Baud rate and Data format on an Ethernet-equipped sign
On signs that are Ethernet equipped, the Baud rate and Data format of the sign’s internal Ethernet card
must be identical to the Baud rate and Data format of:
• the sign’s internal DIP switches. See “Sign configuration” on page 6.
• the computer that is running the messaging software used to send messages to the sign.
To change the Baud rate and Data format of the sign’s internal Ethernet card, follow these steps:
1. Using the Configuration Utility software supplied with the sign, select Telnet to Device. The current
Baud rate, Data format (called I/F Mode), and other communication parameters will be displayed:
2. Select 1 for Channel 1 Configuration. Then set the various parameters as you are prompted:
Parameters of the sign’s internal Ethernet card:
• Baudrate 9600 – Factory setting. Can be changed.
• I/F Mode (see table below) – This is a hexadecimal
number (4C in this example) that sets the network
type (RS232, internal to the sign), number of data bits
(7/8), parity (None/Odd/Even), and number of stop
bits (1/2).
Examples:
Data format (I/F Mode) table
Option
Binary Code
76543210
Network
Type
RS232
00
Number of
Data Bits
7 bit
10
8 bit
11
Parity
None
00
Even
11
Odd
01
Number of
Stop Bits
1 bit
01
2 bits
11
Options Binary Code
Hexa-
decimal
Number
RS232, 8-bit, No parity, 1 stop bit 01001100 4C
RS232, 7-bit, Even parity, 1 stop bit 01111000 78
In this example, the new
Baud rate will be 38400.