Specifications
October 8, 2003 Networking Alpha Signs (9700-0112C)
44 Network cables and adapters
Modular Network Adapter (pn 4331-0602)
Description
Typical use
Used to connect a PC to a Converter Box III as part of an RS485 network:
Pinouts
Item Part # Description
A 1088-1111
Converter Box III with a Converter Box III AC Adapter:
pn 4011-1201 (120 volt)
pn 4011-4201 (230 volt)
B
1088-8624 8-foot RS485 cable
1086-8636 1-foot RS485 cable
C 4331-0602 Modular Network Adapter
D
1088-8002 1000-foot RS485 shielded plenum cable
7122-0283 100-foot RS485 shielded plenum cable
7122-0284 100-foot RS485 outdoor-rated shielded plenum cable
E 1088-8634 Type A9 RS232 cable (connects Converter Box III to PC RS232 port)
Left side
RJ11 (female)
Right side
Top
Alpha sign
B
C
A
E
D
PC running messaging
software
Alpha sign
(Red terminal) SHIELD
RS485 – (Yellow terminal)
Green terminal
NOTE: Connecting the SHIELD depends on the sign to which you are connecting. If your
sign has only one RJ11 jack (a combined RS232 and RS485), the shield wire
should not be connected to the red terminal of the modular network adapter.
However, if your sign has two RJ11 jacks, the shield wire should be connected to
the red terminal. Additionally, in the case of a sign with two RJ11 jacks, always
connect the 4-conductor RS485 cable to the RS485-only jack.
RJ11
(female)
Pin
Signal
1 RS485 +
2 SHIELD
3 Not connected (Green terminal)
4 RS485 –
14