Specifications
October 8, 2003 Networking Alpha Signs (9700-0112C)
30 Network interfaces
DIP switch information
Wiring information
Switch(es) Setting Meaning
1, 2, 3 On / On / On 2-wire RS485
4, 5 On/Off 2-wire RS485 termination
6, 7 On / On RX biasing
8 Off Float shield
Revision C13/B or later is needed.
Earlier versions may not work correctly.
If you experience difficulty, contact your
Customer Account Specialist.
On
Off
12345678
DIP switches with RS485 termination
METHOD 1 — SERIAL I/O terminal block connection:
METHOD 2 — SERIAL PORT connection:
GND (Blue)
RS232 RXD (Orange)
RS232 TXD (Green)
RS485 - (Red)
RS485 + (Black)
SHIELD
RS485 - (Red)
SHIELD
RS485 + (Black)
SERIAL PORT (on Controller board)
SERIAL I/O
terminal block
2
3
4
6
7
SERIAL PORT (on Controller board)
6
7
RS485 +
RS485 -
SHIELD
From
Etherne
t
Serial
Server
}
LANTRONIX
MSS485-T
serial
console
6vdcreset10BASE-T
power
link
ok
serial
SHLD
TXA
TXB
There are two methods of wiring an Ethernet Serial Server to a sign:
METHOD 1: If a sign has a SERIAL I/O terminal block, then wire the
Ethernet Serial Server to this block (above).
METHOD 2: Otherwise, wire the Ethernet Serial Server directly to the
SERIAL PORT on the sign's Controller board (right).