User's Manual
8
Users to be considered
A) Installation personnel – only by manufacturer trained and authorized technician
B) Maintenance/repair personnel – only by manufacturer trained and authorize technician
C) Operating personnel – not in consideration for the graphical images at this stage
As there are none to consider, however user interfaces such as OSD and control buttons
shall be considered.
Installation and OSD adjusting should only be carried by manufacturer trained and
authorized personnel.
Technical data
The monitor is intended for indoor use
Operating Temperature : 0~40°C
Operating Humidity : 10%~90% RH (non-condensing)
Operating Pressure : 70 kPa-106 kPa
Storage/Transport Temperature: -20 ~ +60°C
Storage/Transport Humidity :10% ~ 90% RH (non-condensing)
Storage/Transport Pressure : 50 kPa-106 kPa
Rating : DC9-36V – 4.5-1.1A
Operating Principle
The scaler is configured with a high-speed integrated triple-ADC(VGA) , an integrated HDMI
receiver, a high quality display processing engine, an integrated micro-controller and output
LVDS panel interface format.
The user can select the signal ports by front key of monitor then the scaler processing these
signals as zoom in or out action to fit the panel resolution. Then through the cable line
transmission LVDS signals to one of the LCD module.
The last by the clock controller (Timing Controller, TCON), the clock signal is transmitted to
the drive IC on the panel and turn on Backlight for LCD module light source by Scaler
control.