Removing and Replacing Enclosure Components
Replacing an I/O Module
This section provides basic information about your Storage
Enclosure’s I/O modules, including removal and installation
instructions.
Two I/O modules are located on the rear of the Storage Enclosure,
and they are interface-specific. A blank I/O module may also be
available for single I/O module configurations.
(For detailed information about your I/O modules, see the chapter
dedicated to your specific interface:
For a SATA interface (Adaptec FS4100 or FS4500), see
Chapter 5.
For an FC interface (Adaptec FC4100), see Chapter 6.
For an Ultra320 SCSI interface (Adaptec SC4100), see Chapter 7.
To maintain proper airflow and cooling, either an I/O module or
an I/O blank must be installed in both of the Storage Enclosure’s
I/O slots.
Caution: The I/O modules on the SC4100 are not hot-
swappable. Do not attempt to hot-swap SCSI I/O modules.
Caution: Although SATA and FC I/O modules are hot-
swappable, Adaptec highly recommends that you power off the
Storage Enclosure before removing or installing any I/O
module. Hot-swapping an I/O module may result in data
loss or damage to the module and enclosure electronics.
Removing an I/O Module
To remove an I/O module from the Storage Enclosure:
1 Power off the host system and enclosure.
!
!