User`s guide

number or serial number.
- In dual-controller systems, the controller order in maxView
Storage Manager and the BIOS differs. Example: with an
Adaptec 72405 and 7805 installed, the BIOS reports
the 72405 as controller 1 and the 7805 as controller 2;
in the GUI, the controller order is reversed.
- On CentOS 5.8 x64, email notifications may not be sent for
logical drive creations, degraded logical drives, or logical
drives that are rebuilding or fully rebuilt.
- In this release, maxView Storage Manager does not show connector
information for SGPIO enclosures.
- To "uninitialize" a physical drive, use ARCCONF or the BIOS.
maxView Storage Manager does not support the uninitialize
action in this release.
- maxView Storage Manager can "see" RAID controllers operating
in HBA mode or Auto-Volume mode. However, to change the
controller mode, you must use ARCCONF or the BIOS.
- We do not recommend performing a RAID-level migration (RLM)
or Online Capacity Expansion (OCE) on a logical drive with
maxCache enabled.
- Always allow a RAID-level migration to complete before creating
a support archive file. Otherwise, the support archive will
include incorrect partition information. Once the migration is
complete, the partition information will be reported correctly.
- When using maxView Storage Manager and the CLI concurrently,
configuration changes may not appear in the maxView Storage
Manager GUI until you refresh the display (by pressing F5).
- Configuration changes may not appear in the GUI immediately.
4.4.1 Browser Issues
- With Microsoft Internet Explorer 8.0.7601, maxView
Storage Manager displays two 'Unassign Spare' icons on the
ribbon, in the Physical Disk group; one on the first row,
the other on the second. Only the one on the first row is
enabled.
- With Microsoft Internet Explorer 10, the controller
firmware update wizard does not show the f/w update
file name when the upload completes; click Next, then
Back to refresh the display.
- With Apple Safari, the controller firmware update wizard
supports loading only one f/w update file at a time. Trying
to load multiple files fails with an "invalid size" error.
4.4.2 Remote System Issues
On Linux, maxView Storage Manager may fail to connect with
remote Linux or Solaris systems, returning an "Add system
operation Failed" message. To avoid this problem, add the
local host IP address in the property 'localip' in the
configuration file /usr/StorMan/config/server.properties;
for example, localip=10.16.32.25. The remote system will
read this IP address if it does not find a proper IP
address during the connection process.
4.5 Power Management
- Power management is not supported under FreeBSD.
- In maxView Storage Manager, the power management setting in
6