User`s guide

the MaxIQ cache.
4.27 Some SSDs Appear as SATA Drives
Some solid state drives (such as the MemoRight MR25.2-S032G)
identify themselves as ROTATING media. As a result, these SSDs:
o Appear as SATA drives in the ASM Physical Devices View
o Cannot be used as Adaptec MaxIQ cache devices
o Cannot be used within a hybrid RAID array (comprised of
SSDs and hard disks)
4.28 Mismatch in RAID x0 creation in BIOS and ASM
The BIOS utility creates RAID x0 arrays with an odd number of
drives by default. Adaptec Storage Manager creates RAID x0
arrays with an even number of drives by default.
4.29 WDC WD3200BJKT-00F4T SATA Drives with Promise J630 Enclosures
A compatibility issue between Western Digital WD3200BJKT-00F4T
SATA drives and Promise J630 enclosures can result in a firmware
crash during a RAID array build or bus rescan.
4.30 SATA 6G Drives Not Detected on Promise and Intel Backplanes
o With Promise J830s enclosures, SATA 6G drives are reported as
3G in ASM and the BIOS utility, due to a speed negotiation
issue between the drive and the expander.
o With Intel AXX6DRV3G and AXX6DRV3GEXP backplanes, SATA 6G drives
are not detected in the BIOS. With Intel AXX6DRV3G backplanes,
the BIOS hangs; with Intel AXX6DRV3GEXP backplanes, no drives
are detected in the BIOS utility.
4.31 Samsung Spinpoint SATA Drives Timeout on I/O Load
With Samsung Spinpoint SATA drives, models HD103UJ/HD103UI/HE103UJ,
the controller can reset due to a timeout when the drive is under
heavy I/O load.
4.32 RAID Array Creation Issue With STEC MACH 8 SSDs
With STEC MACH 8 SSDs with firmware version 1766, RAID array
creation fails when using the Adaptec Storage Manager wizard.
WORKAROUND: Upgrade to the latest STEC firmware version to
resolve the problem.
--------------------------------------------------------------------
(c) 2011 PMC-Sierra, Inc. All Rights Reserved.
This software is protected under international copyright laws and
treaties. It may only be used in accordance with the terms
of its accompanying license agreement.
The information in this document is proprietary and confidential to
PMC-Sierra, Inc., and for its customers' internal use. In any event,
no part of this document may be reproduced or redistributed in any
form without the express written consent of PMC-Sierra, Inc.,
1380 Bordeaux Drive, Sunnyvale, CA 94089.
P/N DOC-01651-02-A Rev A
8