User`s guide
NOTE: Mixing SATA and SAS drives in the same logical device
is not recommended.
4.31 Xtore and Xyratex Enclosure Timeout
o With Adaptec Series 2, 5, and 6 controllers, Xtore XJ-SA12-005
and XJ-SA26-224R-S enclosures timeout when they receive a
Diagnostic Page 04 command. The error occurs at approximately
10 minute intervals (and is reported in the ASM controller
log file), but has little or no effect on performance.
o With Adaptec Series 5 controllers, Xyratex RS-1603-E3-EBD-2
enclosures periodically timeout when they receive a SES2
diagnostic command, due to a protocol violation. The error
occurs at 5 to 15 minute intervals, and may degrade performance.
4.32 Boot delay with Plextor PX-716SA DVD-ROM Drive
When booting from a Plextor PX-716SA DVD-ROM drive attached
directly to an Adaptec controller, the boot appears to fail
with a "Could not find boot CD-ROM" error, but resumes
and boots successfully if you wait approximately 30 seconds
or until the front LED light turns green.
4.33 Series 6 Controllers Hang on Warm Reboot on Some ASUS Motherboards
Due to a PCIe configuration problem with ASUS P7P55-WS, KCMA-D8,
and KGPE-D16 motherboards, Adaptec Series 6 controllers may hang
on warm reboot if installed in a slot with x8 links. (The problem
is not seen with Adaptec Series 5 controllers.)
WORKAROUND: Use a slot with x16 links.
4.34 HDA Mode Reset for Adaptec Series 6 Controllers
Adaptec Series 6 controllers do not support Mode 0 reset, using
the AFU utility on the Adaptec Installation DVD. To flash
a Series 6 controller using the HDA mode jumper on the controller
board, you must use the PFU.exe utility, which uses a FDL
firmware file (as opposed to a UFI file) to reset the board.
PFU.exe is available only from your Adaptec by PMC service
representative; it is not included on the installation DVD. For
the location of the HDA jumper on Series 6 controllers, see the
user's guide.
--------------------------------------------------------------------
(c) 2012 PMC-Sierra, Inc. All Rights Reserved.
This software is protected under international copyright laws and
treaties. It may only be used in accordance with the terms
of its accompanying license agreement.
The information in this document is proprietary and confidential to
PMC-Sierra, Inc., and for its customers' internal use. In any event,
no part of this document may be reproduced or redistributed in any
form without the express written consent of PMC-Sierra, Inc.,
1380 Bordeaux Drive, Sunnyvale, CA 94089.
P/N DOC-01699-01-A Rev B
9