User`s guide

7-8
Troubleshooting
Warning and Error Events
There are a number of conditions that trigger warning or error
events, activate the audible alarm, and may affect the state of the
Status and Fault LEDs. The audible alarm sounds mainly when
Adaptec Disk Array Administrator displays a warning or error
event.
Table 7-1 and Table 7-2 provide a list of warning and error events
and recommended actions to take to fix the problems.
Warnings
Warning events let you know that something related to the
controller or an array has a problem. You should correct the
problem as soon as possible. Table 7-1 defines each warning event
and recommends the action you should take.
Table 7-1 Warning Events
Event Definition Recommended Action
ARRAY
CRITICAL
One or more disk
drives were downed
and the array is online,
but is no longer fault
tolerant.
Add a spare to the array or
the spare pool. Then
replace the bad disk
drives. See Adding a
Dedicated Spare on
page 4-2 or Adding a Spare
to the Spare Pool on
page 4-5.
ARRAY
OFFLINE
One disk drive in a
RAID 0 or volume set
went down, bringing
the array to an offline
state. This array is no
longer accessible by
the host.
Replace the bad disk drive
and restore the data from
backup.
BATT FAIL
INFO
A warning condition in
the battery pack and/
or charging interface
has been detected.
Replace the battery. Refer
to the DuraStor 6200SR and
312R Installation and Users
Guide.