Datasheet

C-35
Command Line Interface (CLI)
enclosure prepare slot {enclosure} {slot}
Prepares a device in a slot for insertion/removal.
Parameters
{enclosure}
ID associated with the enclosure management
device on which to prepare a slot.
{slot}
Unit number associated with the slot.
enclosure set alarm [/on={
boolean
}] {enclosure}
Turns the audible alarm on or off.
Parameters
{enclosure}
ID associated with the enclosure management
device whose audible alarm to set.
Switches
/on
Specifies whether to turn the audible alarm on or off.
enclosure set fan [/off={
boolean
}] {enclosure} {fan} [{speed}]
Sets the speed of a specific fan.
Parameters
{enclosure}
ID associated with the enclosure management
device on which to set the speed of a fan.
{fan}
Unit number associated with the fan.
{speed}
Speed at which to set the fan.
Switches
/off
Specifies whether to turn off the fan.
enclosure set interval {second}
Sets the monitor reporting interval (in seconds).
Parameters
{second}
Number of seconds for the monitor reporting
interval.