Installation guide

U41255-J-Z156-1-76 19
Installation Outline for the Cluster setup
Outline for the Cluster setup
To add an RAID array to a Windows 2000 Cluster server:
Ê Assemble everything needed for the installation.
Ê Configure the controller cards as desired for memory and battery backup
capability.
Ê Power the cluster servers down completely.
Ê Install both controller cards in the PRIMERGY Servers.
Ê Install the hard drives in the PRIMERGY S30 Storage Subsystem.
Ê Connect the controller cards to the Dual Input Modules in the
PRIMERGY S30.
ATTENTION!
Make sure that controller channel #0 from Server Node 1 and
controller channel #0 from Server Node 2 are connected to the same
dual channel input module in the S30.
Ê The same rule applies to both channels #1
Ê Boot Node 2 and enter into SMOR (press Ctrl+A on request during boot).
Ê Change on BUS0 and BUS1 Controller SCSI ID´s from 7 (default) to 6.
ATTENTION!
Change the controller ID on both busses.
Ê Enable the Cluster support.
The SMOR option to enable/disable cluster support is hidden. To
enable the cluster support option in SMOR, you need to highlight the
HBA and go into the configuration screen with pressing ALT+C, then
press ALT+F10and ALT+ D. The hidden cluster option (Cluster Server
Enable) will be visible now.
Ê Save changes >exit > power off Node 2.
Ê Boot Node 1 and enter into SMOR.
!
!
i