Installation guide

U41255-J-Z156-1-76 15
Installation Installing the 3200S RAID Controller
Jumper Settings
There are no jumpers settings that need to be set on any Adaptec controllers to
set-up for cluster operation. Jumper settings that are available are covered in
the installation guide.
Ê Attach the module to the controller, connecting P12 on the Battery Backup
Module to J12 on the controller.
Installing the 3200S RAID Controller card into the
server
Both servers will need to have the controller card installed as follows:
Same slot occupation within the PRIMERGY nodes
Same BIOS/FW of RAID controllers
Same cache size of RAID controllers
Both RAID controllers with or without battery backup unit
The 3200S RAID controller can be plugged into a 32-bit or 64-bit PCI slot that
receives 5 V, and, optionally, 3.3 V through the motherboard.
Ê Choose a PCI slot and align the 3200S RAID controller card edge connector
into the slot.
If an existing SCSI controller will continue to be used as the boot
controller, the RAID controller must be positioned in a slot that will
allow the existing controller to continue to be primary.
Ê Insert and secure the RAID controller into the PCI slot.
i