Installation guide
U41255-J-Z156-1-76 13
Installation
Configuring the 3200S RAID Controller
This section shows how to install and setup the 3200S RAID controller and
connect both nodes to the PRIMERGY S30 Storage Subsystem.
The following installation instructions require both server nodes in the cluster
server to be powered down for the installation of the controller cards.
Install Memory Cache
The 3200S RAID controllers have 1x 32MB or 2x32MB of memory installed as
shipped from the factory. If you have a controller with 1x32MB and you wish to
make the available memory cache larger, you will need to add memory.
3200S RAID controllers have two memory sockets. If only one is populated as
shipped the simplest upgrade or addition is performed by simply adding a
memory module to the second socket.
Ê Install the cache memory SO-DIMMs on the RAID controller card in the
cache memory socket.
Ê Use only an SO-DIMM supplied for the 3200S RAID controller.
The SO-DIMMs must be parallel to the RAID card when properly
installed.
Ê The picture below shows the memory installation. Use this method to install
cache memory.
i